home *** CD-ROM | disk | FTP | other *** search
- AutoCAD 10, 11, 12 and 13 Installation Notes
- ***********************************************************************
-
- READ THIS FILE COMPLETELY BEFORE ATTEMPTING TO USE THIS PRODUCT !
-
- You must run QUICK SETUP from the Main Menu and select an appropriate
- monitor type, prior to installing the AutoCAD Display Driver.
-
- IMPORTANT: This driver is intended for use with AutoCAD Release 10/386,
- 11, 12 and 13, Protected mode only.
-
- ****************************
-
- 1.0 Installation Notes for AutoCAD 386
-
- 1) Make sure AutoCAD has already been installed on your hard drive.
-
- 2) To complete the install successfully, you will require the following
- information:
-
- a) The full path name of the AutoCAD directory.
- b) The ATI batch file is called ADIACAD.BAT for AutoCAD 10 and 11.
-
- 3) From the "Drivers Installation" menu, select AutoCAD.
-
- 4) When INSTALL has completed copying all necessary files, exit the
- program.
-
- 5) Please note that if you install the 386 Protected mode driver files
- into an alternate sub-directory, you will have to alter your ACADDRV
- environment variable in your AutoCAD batch file to include the alternate
- 386 Protected mode driver sub-directory.
-
- E.g.: Default environment variable for AutoCAD, release 12
- SET ACADDRV = C:\ACAD\DRV
- After alteration SET ACADDRV = C:\ACAD\DRV;C:\ATI_DRV
-
- Default environment variable for AutoCAD release 13
- SET ACADDRV = C:\ACADR13\DOS\DRV
- After alteration SET ACADDRV = C:\ACADR13\DOS\DRV;C:\ATI_DRV
-
- Note: Where ATI_DRV is your alternate 386 Protected mode driver
- sub-directory.
-
- Note: For AutoCAD release 10 and 11 (Protected Mode) see instructions #7.
-
- 6) For AutoCAD, release 12 and 13 follow these steps:
-
- a) In the AutoCAD directory, run AutoCAD with the option -R to
- configure the video display (e.g. : ACADR12 -R).
- b) Select 3. Configure video display.
- c) Select TurboDLD Classic...
- d) Select the appropriate graphics card from the list.
- e) Select the desired resolution and color depth.
-
- 7) For AutoCAD, release 10 and 11 follow these steps:
-
- a) Go to the directory where the 386 Protected mode driver files
- are installed and run ADIACAD.BAT
- b) In the AutoCAD directory, run AutoCAD to configure the driver.
- c) Enter the Configuration menu.
- d) Select Configure Video Display.
- e) select "ADI P386 v4.0/4.1 ...".
- f) Select the desired resolution and color depth.
-
- 8) For further details, please see MANUAL.TXT and README.DLD after
- installing the driver. The files will be copied to user-specified
- DRIVER sub-directory.
-